Home > System Call > System Call Error Number 3474

System Call Error Number 3474

Contents

Please try the request again. Check the application for massive storage allocation call. 55 ENOBUFS Accept Not enough buffer space is available to create the new socket. See the Connect() description for possible responses. 36 EINPROGRESS IOCTL (SIOCTTLSCTL requesting TTLS_INIT_ CONNECTION or TTLS_STOP_ CONNECTION) The handshake is already in progress and the socket is a non-blocking socket. There was a similar error that IBM fixed in 2007 related to SSL in FTP... his comment is here

For Bind() and Connect(), set Sin_Family in the socket address structure to AF_INET. 47 EAFNOSUPPORT Getclient Givesocket The socket specified by the socket descriptor parameter was not created in the AF_INET Order your copy at SQLThing.com today! I'm thinking that if something is damaged and can't initialize, could we grab another by doing a close and another init? Verify TCP/IP is active. 1016 EIBMTCPABEND All An abend occurred when TCP/IP was processing this request.

Cpfa0d4 3401

Call your MVS system programmer. 2017 EIPADDRNOTFOUND REXX Address not found. Call your MVS system programmer. 2012 EINVALIDNAME REXX An incorrect name was received from the TCP/IP server. Sign Up We never spam! Issue the SIOCTTLSCTL IOCTL on TCP sockets only. 41 EPROTOTYPE IOCTL (SIOCSAPPLDATA) The request was not successful.

So now I go back to the job log you sent on Tuesday, and I see this: *NONE Command 01/19/11 22:01:00.030472 QCLCLCPR QSYS 04A4 PPR200P MODHPGM *STMT To module . . Ensure the NODE or HOST name can be resolved. 1 EDOM All Argument too large. Check socket descriptor value. This error can be caused by any number of situations.

To report a problem, on the cheap, you could try: http://www-912.ibm.com/supporthome.nsf/document/10000043 Rob Berendt -- "They that can give up essential liberty to obtain a little temporary safety deserve neither liberty nor Cpfa0d4 Error 3025 Call your system administrator. 55 ENOBUFS IOCTL (SIOCSAPPLDATA) There is no storage available to store the associated data. Verify that TCP/IP has restarted. 1023 EIBMTERMERROR All Encountered a terminating error while processing. Call your system administrator. 86 EPROTO IOCTL (SIOCTTLSCTL requesting TTLS_RESET_ SESSION, TTLS_RESET_ CIPHER, TTLS_STOP_ CONNECTION, or TTLS_ALLOW_ HSTIMEOUT) One of the following errors occurred: A TTLS_INIT_ CONNECTION request has not been

Data or condition might not be available at this time. 12 ENOMEM All There is not enough storage. Request TTLS_RESET_CIPHER or TTLS_STOP_ CONNECTION only on connections secured using SSL version 3 or TLS version 1. Correct the specified address. 49 EADDRNOTAVAIL IP_BLOCK_SOURCE, IP_ADD_SOURCE_ MEMBERSHIP, MCAST_BLOCK_SOURCE, MCAST_JOIN_SOURCE_ GROUP A duplicate source IP address is specified on the multicast group and interface pair. This is not an error condition.

Cpfa0d4 Error 3025

Restart specified host. 65 EHOSTUNREACH All There is no route to the host. Check the validity of function parameters. 9 EBADF Select One of the specified descriptor sets is an incorrect socket descriptor. Cpfa0d4 3401 Reestablish the connection between the applications. 54 ECONNRESET All The connection to the destination host is not available. Check the validity of function parameters. 15 ENOTBLK All A block device is required.

The select/selectex would never complete. this content Call your system administrator. 82 ENOLINK All The link has been severed. Call your system administrator. 89 EREMCHG All The remote address has changed. WRKOBJ OBJ(*ALL/Command_Name) OBJTYPE(*CMD) If multiple versions of the command exist, then the library list of the job where the error occurs should be examined to see if a copy of the

This thread ... ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.8/ Connection to 0.0.0.8 failed. This command is not supported for this function. weblink Check and correct all function parameters. 121 EINVAL IOCTL (SIOCSAPPLDATA) The input parameter is not a correctly formatted SetApplData structure.

Is that by design? _______________________________________________ This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: [email protected] To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/cgi-bin/listinfo/midrange-l or Issue the SIOCTTLSCTL IOCTL only after the socket is connected. 58 ESHUTDOWN All A Send cannot be processed after socket shutdown. For GETNAMEINFO, HOST could not be resolved within the configured time interval.

Reissue after previous call has completed. 1036 EIBMNOACTIVETCP All TCP/IP is not installed or not active.

Check status and contents of source database if this occurred during a file access. 6 EAI_MEMORY GETADDRINFO GETNAMEINFO The resolver cannot obtain storage to process the host name. When repeated it runs really fast, even in other sessions for the first time. Arner, Jr., is a programmer who has published extensively on AS/400 integration and database topics. Specify the correct value. 23 ENFILE All Data set table overflow occurred.

Is there a PTF for this? c eval rc = gsk_environment_init(wkEnvh) c if rc <> GSK_OK c if rc = GSK_AS400_ERROR_NOT_REGISTERED c callp SetError(HTTP_NOTREG: 'Application ' + c 'is not registered with DCM!') c callp https_cleanup c Call your system programmer. 1038 EIBMINVUSERDATA All The request control block contained user data that is not valid. check over here This is not an error condition.

Use of the archive is restricted to research of a business or technical nature. http://www.scottklement.com/mailman/listinfo/ftpapi ----------------------------------------------------------------------- This is the FTPAPI mailing list. Check that TPC/IP is still active; check protocol value of socket () call. 1 EPERM IOCTL (SIOCTTLSCTL requesting both TTLS_INIT_ CONNECTION and TTLS_RESET_ SESSION or both TTLS_INIT_ CONNECTION and TTLS_RESET_ CIPHER) Check the offset parameter for seek operation. 30 EROFS All The data set system is Read only.

See any messages in the job log and correct any errors that may indicated (sic) and then retry the operation. There is no such connection. Ensure user ID has authority for the specified operation. 1015 EIBMBADCONNECTIONMATCH All A connection token that is not valid was detected. Correct the name specified in the IBM_TCPIMAGE structure. 1011 EIBMBADTCPNAME Setibmopt A TCP/IP name that is not valid was detected.

Remove or rename existing file. 18 EXDEV All This is a cross-device link. Diagnosing the problem File system error 3474 (which signals that an error CPE3474 occurred) means "Unknown System State". Check the validity of function parameters. 14 EFAULT IOCTL (SIOCSAPPLDATA) An abend occurred while attempting to copy the SetADcontainer structure from the address provided in the SetAD_ptr field. http://www-01.ibm.com/support/docview.wss?uid=nas21f5728dac1be65a986257331003c69c5 4.

The system returned: (22) Invalid argument The remote host or network may be down. The SetAD_eye1 value is not valid. Joe Hertvik wrote "Admin Alert: Four Steps to Creating a Subsystem," which you may also find useful.