Home > Symantec Error > Symantec Error Invalid Machine Uuid

Symantec Error Invalid Machine Uuid

Contents

Otherwise, select this option.Click NextClick FinishClick OK, allow the recovery to finish, remove the Recovery disk and reboot the machine.Enter the pass phrase on the PGP screen.When the error Missing Operating System appears, boot the machine It is also important that the Disk ID value for the --list-user output, matches the value for MACHINEGUID in the registry of the host machine for disk 0 (boot disk). When using the tool in this way, ensure the user running this command has administrative privileges in order to successfully run. occur during IBM Rational ClearCase dynamic views with Symantec 12.1.6 . this contact form

Download Files A walkthrough on using the PGPWdeUpdateMachineUUID.exe utility Using_PGPWdeUpdateMachineUUID.exe_Utility.pdf (543.5 KB) Terms of use for this information are found in Legal Notices. Browse to the users %appdata%\PGPCorporation folder and delete the PGPprefs.xml and PGPpolicy.xml files. No Yes ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.9/ Connection to 0.0.0.9 failed. The following steps are a 'work-around' in situations where a restore is imperative, and is not a guarantee of a successful restore.   To successfully restore disks encrypted with Symantec Drive

Pgpwdeupdatemachineuuid.exe Download

Close Sign In Print Article Products Related Articles Article Languages Subscribe to this Article Manage your Subscriptions Problem How to restore disks encrypted with Symantec Drive Encryption with Symantec System Recovery Change to the Program Files directory for Symantec Encryption Desktop: cd c:\Program Files\PGPCorporation\PGPDesktop (32-bit) or cdc:\Program Files (x86)\PGPCorporation\PGPDesktop (64-bit) 5. Applies ToEnterprise environments commonly use images (System Images, Golden Images, Base Images, Corporate Images, etc.) in order to configure machines to a pristine, working state.Sometimes Symantec Drive Encryption is included as Scenario 1: Verify the MACHINEGUID or Disk IDthat exists in the registry is not a duplicate: WARNING: Please do not modifyPGP registry entries manually.Doing so can cause invalid data to be

Solution DISCLAIMER: At this time, restoring volume(s) encrypted with Symantec Drive Encryption software is not currently supported by Symantec. Don't have a SymAccount? For more information, see the Symantec Knowledgebase article TECH201455 (http://www.symantec.com/docs/TECH201455). [3057427] Resolved an issue with a potential buffer overflow in Symantec Drive Encryption running on Microsoft Windows XP or Microsoft Windows If so, follow the process outlined by support using the tool previously mentioned.

For more information, see the Symantec Knowledgebase article TECH201455 (http://www.symantec.com/docs/TECH201455). [3059358] Resolved an issue where Macintosh systems did not boot up while external drives protected by Apple FileVault were connected. [3060554] Your cache administrator is webmaster. WARNING: Deploying Symantec Drive Encryption 10.3.1 or earlier as an installed application is strictly unsupported. Saving config sync.dat I … Symantec … system's logging facility and may be exploited by attackers to execute arbitrary code with elevated privileges.

Terms of use for this information are found in Legal Notices. Create a SymAccount now!' Unable to upload a whole disk recovery token to Symantec Encryption Management server TECH149228 December 5th, 2013 http://www.symantec.com/docs/TECH149228 Support / Unable to upload a whole disk recovery Close Login Didn't find the article you were looking for? If an affected user has multiple systems or devices associated to the end user's account, check to make sure the other system or device is not also affected by this duplicate

Machineguid

Create/Manage Case QUESTIONS? This issue can be exploited by remote attackers by asserting invalid requests. Pgpwdeupdatemachineuuid.exe Download Submit a Threat Submit a suspected infected fileto Symantec. In addition to having duplicate MACHINEGUID values, or Disk UUID values set for each device, users on Symantec Encryption Management Server will have all other users who have the same MACHINEGUIDvalue

Scenario for Symantec Drive Encryption for versions not listed above: Consult with Support on how best to resolve the issue. http://allconverter.net/symantec-error/symantec-error-2324.html Try these resources. Submit a Threat Submit a suspected infected fileto Symantec. PGP error : -11996 Operation failed: Failed to update PGP metadata.

This MACHINEGUID entry uses the following convention for its value data: {A25F4A63-338B-4B6C-AD44-C7D7E0C59662} Upon starting the Symantec Drive Encryption process on a machine, the value for MACHINEGUID is then linked to A username is now a required parameter for this command. [2688280] Resolved the issue in Symantec Drive Encryption where PGP Bootguard freezes if a built-in webcam is enabled in the BIOS Reinstall Symantec Encryption Desktop. navigate here Solution If it is identified that the users areaffected, Symantec Support has a toolcalledPGPwdeupdatemachineUUID.exethat can be provided to help resolve the duplicate MACHINEGUIDvalues on versions 10.1.x, 10.2.x, 10.3.0, 10.3.1, and 10.3.2.

Email Address (Optional) Your feedback has been submitted successfully! NOTE:If external hard disks are being used, it is possible for these external drives to have different Disk ID values than the MACHINEGUID value--this is normal. This document helps the administrator understand how to change the MACHINEGUID on a client computer with the PGPwdeupdatemachineUUID.exe utility if multiple computers in the environment have the same MACHINEGUID, with the

Reboot the computer.

After the reinstalling, exit PGPServices by right-clicking on the PGP Tray icon and selectingExit PGP Services. Description: Jan 28, 2009 9, The storage control block address is invalid. . 216, The image file %1 is valid, but is for a machine type other than the current machine. Before deploying this utility to affected systems, it is recommended that a sample of affected systems be tested to ensure the process chosen successfully updates the MACHINEGUID value, as well as Education Services Maximize your product competency and validate technical knowledge to gain the most benefit from your IT investments.

Products Products Home Threat Protection Advanced Threat Protection Endpoint Protection Endpoint Protection Cloud IT Management Suite Email Security.cloud Data Center Security Blue Coat Products Information Protection Data Loss Prevention Encryption VIP No Yes How can we make this article more helpful? Only Symantec Drive Encryption 10.3.2 can be used to be included as an installed application in a system image. http://allconverter.net/symantec-error/symantec-errors.html Sorry, we couldn't post your feedback right now, please try again later.

It is possible that updates have been made to the original version after this document was translated and published. NOTE:A walk through of using the PGPwdeupdatemachineUUID.exeas well as troubleshooting steps is attached to this article. Local Execution You can run the utility locally on a computer using the following steps: To run the utility locally from Windows Explorer Right-click the PGP Tray icon and select Exit It is also good to find multiple affected systems and run this same command to determine who is affected and has the same MACHINEGUID or Disk UUID values.

Verify that you don't have a duplicate MACHINEGUID as described in scenario 1 and then upgrade your environment to the latest version of SymantecEncryption Management Server and Symantec Encryption Desktop. Make sure that you reboot the computer when prompted. The remaining steps will erase and then overwrite the selected disk contents.***Type clean all and press Enter. (This removes any and all partition or volume formatting from the disk selected in Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue?

If the command was run with the “--interactive” option, the user was prompted only for the passphrase and not the username. To run the utility locallyvia the command line Right-click the PGP Tray icon and select Exit PGP Services. Doing so is currently supported with Symantec Drive Encryption 10.3.2 and later, however all previous versions are susceptible to duplicate MACHINEGUID values causing invalid\incorrect Drive Encryption data being sent to the Thank you for your feedback!

No Yes CompHelp - Menu Skip to content Home Symantec Error Invalid Machine Uuid Posted on May 31, 2015 by admin Symantec Internet Security and others. Determine which invalid devices are associated to the users account on Symantec Encryption Management Serverand remove them, leaving only the most recent device for the affected systems.