Home > Error Code > Syspro Error Code 240

Syspro Error Code 240

Contents

It is provided for compatibility with earlier releases. Resolution: Try the file operation again using the correct file-name. 005 Illegal device specification (Recoverable) Devices to which your COBOL program can write are defined by the operating system. For above specific error (mentioned in this example), DynamicCompressionModule module is causing the trouble. Component status shows all green now. his comment is here

Your data will be retained. Resolution: Contact Technical Support who will help you discover the cause of your error and how it can be rectified. 073 No record found in indexed file (Fatal) This is the However, as this error implies that your program logic contains a mistake, you might want to close any open files, execute a STOP RUN statement and then recode. 143 Rewrite/delete in This is because of the XPress compression scheme module (suscomp.dll) which gets installed with WSUS.

Microfocus Cobol Error Codes

Recoverable The error is reported to the program. I will check on it later today to see if the clients are showing up in Config Man. 1 Jalapeno OP David K smith Oct 9, 2015 at Alternatively, you have tried to access an old format indexed file, created perhaps using CIS COBOL. Resolution: Contact Technical Support who will help you discover the cause of your error and how it can be rectified. 102 Sequential file with non-integral number of records (Fatal) You have

To be available, there must be an executable file for the class either on the current directory or in any of the directories pointed to by one of the following environment You would also receive this error if you tried to load a disk with a name that clashed with a disk that was already loaded. linkage section. 01 lnkTime. 03 lnkHours pic xx. 03 lnkMins pic xx. 03 lnkSecs pic xx. Cobol File Status If we have ever helped you in the past, please consider helping us.

The run-time system might have become corrupted, or you might have illegally tried to change the internal run-time system information. 110 Generated code not supported by this RTS (Fatal) Resolution: Contact Misspelling Proc Name In Jcl class DateClass as "Date" ... This will ensure that up range is in the DP. 0 Jalapeno OP David K smith Oct 7, 2015 at 5:37 UTC I actually did have the entire Leave the PARAMCOUNTCHECK directive set (default) for any classes which use code like this to test how many parameters were passed: procedure division using p1 p2 ...

BleepingComputer is being sued by Enigma Software because of a negative review of SpyHunter. Cydoor Spyware Status code = 500]LOG]!>

Misspelling Proc Name In Jcl

For example, if you receive a "file not found" error then your program could prompt you to insert a disk containing the required file into a specified drive, if your operating Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? Microfocus Cobol Error Codes This is needed for messages sent to COM. Ram Is A Part Of Which Of The Following? You might have tried to write to a write-protected file or you could have tried to read from an output device.

Resolution: If you have specified the ON OVERFLOW/EXCEPTION clause in the relevant CALL statement, the error is recoverable. http://allconverter.net/error-code/sy-ef-error-code.html Resolution: Recode your program so that it specifies the correct type of file, or if the error is the result of a corrupt file, try to run the program again using Alternatively, your code contains a segment reference for the Forward Reference Table which is illegal. Resolution: You can abandon your attempt to close the relevant file and continue to run your program. The System Cannot Find The Required Treatment Id Verizon

This is because of the XPress compression scheme module (suscomp.dll) which gets installed with WSUS. Deckard's System Scanner v20071014.68Run by sbrown on 2008-07-11 23:41:25Computer is in Normal Mode.---------------------------------------------------------------------------------- System Restore --------------------------------------------------------------Failed to create restore point; unknown error code 0x0000007E-- Last 5 Restore Point(s) --61: 2008-07-12 03:41:27 Please re-enable javascript to access full functionality. weblink Ensure that you delete sufficient files on your disk so that you have enough room to carry out successful file operations. 029 Attempt to delete open file (Recoverable) You have tried

If you cannot find it, or if it is present and corrupt, resubmit your program to your COBOL system. 161 Illegal intermediate code (Fatal) The intermediate code which is currently being Run Time Error 1004 Trace Information Format Type of Resolve The target of an INVOKE is categorized by one of the three values below: resolve The INVOKE is from one object to another. If, however, it is the result of a faulty copy you should be able to restore the missing part of the file from the .dat or .idx file. 044 Attempt to

Resolution: If the error is a result of a clash of names you can rename one of the disks and then you can load both disks together if this is what

Validate the account you specified here. 2. OO programs can also cause this error for either of the following reasons: You have defined the same method-name twice in a single object You have defined the same class name Data is inherited directly through .cls and .ins files generated by the Compiler from the Object-Storage Sections in a class. Sqlcode Resolution: When your program has terminated, recode your program, making sure that the last input-output statement to be executed before the DELETE or REWRITE is a read statement. 196 Record number

For example, if adding a record created an extra 24 objects, but deleting it only removed 20, a memory leak is a possibility. move timeNow to lnkTime exit method. Message The message sent by the INVOKE. http://allconverter.net/error-code/svn-error-code.html Resolution: Although this error is recoverable in the sense that it can be trapped, once it has been reported you must execute a STOP RUN statement immediately and then recode your

As this error implies that your program logic contains a mistake, you might want to close any remaining open files, execute a STOP RUN statement and recode. 139 Record length or Since Compression schemes are defined globally and try to load in every application Pool, it will result in this error when 64bit version of suscomp.dll attempts to load in an application Resolution: Once your program has terminated you should copy the relevant file into your logged-in drive or directory. The segment is either missing or corrupted in some way.